Enclosed doorglass blinds are thoroughly tested to meet rigorous product code criteria for design pressure requirements and non-impact standards.

Edit

Design Pressure

Design Pressure Requirements

Design Pressure (DP) testing measures the performance of fenestration products to withstand positive and negative pressures. The positive DP number is the standard for wind blowing at the building (windward) and the negative DP number represents the vacuum pressure on the opposite side of the building (leeward).

Design pressure requirements will vary based upon wind zone designation in your geographic location (see Florida map as an example), density of nearby buildings, fenestration height from the ground, fenestration location on the side of the building, etc. Florida has had specific wind zone performance requirements for many years, as found in the Florida Building Code. Other states continue to adopt design pressure requirements.

Design Pressure Testing

Design pressure testing for ODL Blinds + Glass involves testing the enclosed IG blinds as a component of a complete fenestration assembly, such that the IG and its surrounding fenestration are considered together. For doorglass IG blinds, for example, this means testing the IG along with the IG frame and a fixed door. Please refer to a Florida product approval, FL15260, as an example of a product approval which can be used for ODL blinds in a side-hinged door.

design-pressure
Type of ODL Frame Typical Design Pressure Rating* Florida Product Approval Test Method

6'8" Evolve

+/- 60 psf

FL15260.15

TAS 202

8'0" Evolve

+/- 65 psf

FL15260.15

TAS 202

6'8" ZEEL

+/- 60 psf

FL15260.18

TAS 202

8'0" ZEEL

+/- 60 in fiberglass

+/- 50 in steel door

FL15260.19

TAS 202

6'8" TriSYS

+/- 60 psf

FL15260.13

TAS 202

8'0" TriSYS

+/- 60 psf

FL15260.13

TAS 202

Typical Design Pressure Rating*

6'8" Evolve

:

+/- 60 psf

8'0" Evolve

:

+/- 65 psf

6'8" ZEEL

:

+/- 60 psf

8'0" ZEEL

:

+/- 60 in fiberglass

+/- 50 in steel door

6'8" TriSYS

:

+/- 60 psf

8'0" TriSYS

:

+/- 60 psf

Florida Product Approval

6'8" Evolve

:

FL15260.15

8'0" Evolve

:

FL15260.15

6'8" ZEEL

:

FL15260.18

8'0" ZEEL

:

FL15260.19

6'8" TriSYS

:

FL15260.13

8'0" TriSYS

:

FL15260.13

Test Method

6'8" Evolve

:

TAS 202

8'0" Evolve

:

TAS 202

6'8" ZEEL

:

TAS 202

8'0" ZEEL

:

TAS 202

6'8" TriSYS

:

TAS 202

8'0" TriSYS

:

TAS 202

*Unless otherwise specified, design pressure rating refers to most doors tested

Edit
non-impact

Non-impact Component Approval

All sizes and styles of ODL® door glass for side-hinged doors, including ODL Blinds + Glass products, have Florida Product Approvals through the Florida Building Commission (FBC).

ODL Blinds + Glass in side-hinged doors is covered by Florida Product Approval FL15260. This approval allows substitution in any glazed side-hinged door or sidelight. Provided the glazed door or sidelight has a Florida product approval, no additional testing is required. Be sure to provide the component approvals for the door and FL15260 to the building inspector.

Edit

Become an ODL Blinds + Glass Partner

Versatile and quality product, quick lead times, and marketing support from ODL.